Data Logger DR-400
1. Features:
LCD with backlight display,
Two NTC probe (PT1000 optional),
Waterproof panel (IP65),
Large data recording capacity, high accuracy, easy to use and install
Password protection,
Data reservation automatically after power off
2. Technical Parameters:
Temperature range: NTC: -40℃ ~ +120℃
PT1000: -200℃ ~ +650℃
Display: LCD, two line, backlight adjustable
Input: Two NTC probe (PT1000 optional)
Three-digit input (NO or NC)
Recording channel: Two (one optional) channels
Accuracy: NTC: +/-0.5℃ (-40℃ ~ +80℃); 1℃ (other range)
PT1000: +/-0.3℃ (-50℃ ~ +200℃); 1℃ (other range)
Memory capacity: 13000 points ( MAX)
Recording cycle: 1 Min. to 999 Min (adjustable)
Resolution: 0.1℃
Printing output: Mini thermal printer, printer paper wide is 57mm, 40 characters each line
Relay output capacity: SPDT 10A 250V
Power: 12 ~ 24VDC (85-265Vac optional)
Operation temperature Range: -20℃ ~ +50℃