Temperature Controller KT-360
|
Paramete
|
Function
|
Set range
|
Default
|
|
E1
|
Lower setpoint limit
|
-45℃/-45℉~Set temp.
|
-35℃/-31℉
|
|
E2
|
Higher setpoint limit
|
Set temp.~45℃/113℉
|
45℃/113℉
|
|
E3
|
Temp. Return Difference
|
1.0~20.0℃/1.8~36.0℉
|
4.0℃/7.2℉
|
|
E4
|
Comp. start delay time
|
0~10Min
|
2Min
|
|
E5
|
Offset on room temp.
|
-20.0~20.0℃/-36.0~36.0℉
|
0
|
|
E6
|
Offset on evap. temp.
|
-20.0~20.0℃/-36.0~36.0℉
|
0
|
|
C1
|
Temperature unit
|
0=℃ 1=℉
|
0
|
|
F0
|
Defrost Mode
|
0=Electric heater 1=Hot gas
|
0
|
|
F1
|
Defrost Time
|
1~60Min
|
20Min
|
|
F2
|
Defrost Cycle
|
0~24Hr
|
6Hr
|
|
F3
|
Defrost termination temp.
|
0~30℃/32~86℉
|
8℃/46℉
|
|
F4
|
Display during defrost
|
0=Normal display
1=Last value before defrost
|
0
|
|
F5
|
Fan operating function
|
0=Parallel with comp.
1=Continuous running except defrost
|
0
|
|
F6
|
Dripping time
|
0~30Min
|
2Min
|
|
F7
|
Fan operating function after defrost end
|
0=Temperature 1=Time
|
1
|
|
F8
|
Fan start-up temperature after defrosting
|
0~10Min
|
2Min
|
|
F9
|
Fan start temperature after defrosting(evaporator)
|
-30~30℃/-22~86℉
|
5℃/41℉
|